TUPCH059 Dual-mode Beam Current Monitor 1145
 
  • S. Ninomiya, T. Adachi, S. Fukumoto
    KEK, Ibaraki
  • S.H. Hatori, T. Kurita
    WERC, Tsuruga , Fukui
 
  A new type HEREWARD-transformer is developed. The original scheme connects pickup coil to the low impedance input of the amplifier to increase the time constant of the transformer. The new scheme employs negative impedance circuit which realizes perfect cancellation of the coil resistance. Therefore DC component of the beam current can be observed. Since number of winding of the pick up coil is only 100-turns, therefore by using the original scheme with a fast operational amplifier, the transformer can be operated at fast CT mode. Thus the dual mode operation can be realized by single core; the first mode is the slow beam intensity monitor, and the second is a fast response transformer. This operation mode realizes an accurate observation of the beam injection process. In order to make installation easy, the core is divided into two pieces. The magnetic shield from bending field is also installed. This monitor is developed at KEK, and installed into the accelerator at the WAKASA WAN Energy Research Center.