THBO06 The Design of the Center Region of MSC230 Cyclotron 285
 
  • V. Malinin, O. Karamyshev, I.D. Lyapin, D. Popov
    JINR/DLNP, Dubna, Moscow region, Russia
  • T.V. Karamysheva
    Federal Research Center "Computer Science and Control", Russian Academy of Sciences, Moscow, Russia
  • T.V. Karamysheva, A.A. Sinitsa
    JINR, Dubna, Moscow Region, Russia
 
  MSC230 is an innovative efficient medical super-conducting cyclotron for the study and investigation of the conventional proton and FLASH therapy, devel-oped by JINR for its new biomedical research center. The machine has an internal injection system provided by a PIG ion source and, for better efficiency, 4 RF dees connected in the center. Despite these re-strictions, it is possible to create a center region design which allows initial acceleration with minimal losses sufficient for the FLASH therapy. The design and its features presented in this talk.  
slides icon Slides THBO06 [2.456 MB]  
DOI • reference for this paper ※ doi:10.18429/JACoW-CYCLOTRONS2022-THBO06  
About • Received ※ 01 January 2023 — Revised ※ 24 January 2023 — Accepted ※ 28 January 2023 — Issue date ※ 31 January 2023