JACoW logo

Journals of Accelerator Conferences Website (JACoW)

JACoW is a publisher in Geneva, Switzerland that publishes the proceedings of accelerator conferences held around the world by an international collaboration of editors.


RIS citation export for MOPO012: An Embedded Beam Diagnostic Electronics for 230 MeV Superconducting Cyclotron Radial Probe and Scanning Wires

TY  - CONF
AU  - Jiang, T.Y.
AU  - Liu, P.
AU  - Mu, X.
AU  - Song, Q.Q.
AU  - Wang, Y.
AU  - Yin, Z.G.
AU  - Zhang, T.J.
ED  - Zhang, Tianjue
ED  - Schaa, Volker R.W.
ED  - An, Shizhong
ED  - Kiselev, Daniela
ED  - Liu, Yuntao
ED  - Li, Pengzhan
TI  - An Embedded Beam Diagnostic Electronics for 230 MeV Superconducting Cyclotron Radial Probe and Scanning Wires
J2  - Proc. of CYCLOTRONS2022, Beijing, China, 05-09 December 2022
CY  - Beijing, China
T2  - International Conference on Cyclotrons and their Applications
T3  - 23
LA  - english
AB  - For the 230MeV superconducting cyclotron, once again, the differential radial probe has been proven to be crucial for the beam commission procedure. It can provide various information about the particles inside the cyclotron, such as the vertical position, the relative intensity as well as the oscillation frequency and radius, etc. In practice, however, the electronics system suffered from the leaking alternating RF field as well as the static magnetic field. Besides the EM shielding, an absorptive high-frequency filter has been included as the first element of the readout electronics. A high dynamic range readout electronic unit has been included to adapt to the fluctuation of the beam in the hole commissioning phase. The electronics box is designed as a network-attached embedded device so that it can be powered by a POE switch and transmits measurement results via MODBUS protocol. A dedicated digital signal processor and calibration units are also included, together with the ADCs, to facilitate the daily calibration process. The same electronics are used for the beamline wire scan system to determine the position of the beam, with a small improvement at a lower range. The design of this multi-purpose beam diagnostics electronics will be reviewed in this paper, together with several measurement results.
PB  - JACoW Publishing
CP  - Geneva, Switzerland
SP  - 80
EP  - 82
KW  - electron
KW  - electronics
KW  - cyclotron
KW  - diagnostics
KW  - embedded
DA  - 2023/10
PY  - 2023
SN  - 2673-5482
SN  - 978-3-95450-212-7
DO  - doi:10.18429/JACoW-CYCLOTRONS2022-MOPO012
UR  - https://jacow.org/cyclotrons2022/papers/mopo012.pdf
ER  -