Author: Boiesan, T.
Paper Title Page
TUD04 BEST 70P Cyclotron Commissioning at INFN LN Legnaro 241
 
  • V. Sabaiduc, M. Carlson, D. Du, T. Evans, L. AC. Piazza, V. Ryjkov, I. Tarnopolski, P. Zanetti
    Best Theratronics Ltd., Ottawa, Ontario, Canada
  • T. Boiesan, R.R. Johnson, W. Stazyk, K. Suthanthiran, S. Talmor, J. Zhu
    BCSI, Vancouver, Canada
 
  Best Cyclotron Systems Inc (BCSI) designed and manufactured a 70 MeV compact cyclotron for radioisotope production and research applications. The cyclotron has been build at Best Theratronics facility in Ottawa, Canada for the INFN-LNL laboratory in Legnaro, Italy. The cyclotron has external negative hydrogen ion source, four radial sectors with two separated dees in opposite valleys, cryogenic vacuum system and simultaneous beam extraction on opposite lines. The beam intensity is 700 microamps with variable extraction energy between 35 and 70 MeV. The beam commissioning performances at the customer site are reported.  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)