Author: Gubarev, V.
Paper Title Page
THPO035 Comparison of Field Emission at Different SRF Cavity Assembly States and Test Stands 795
 
  • D. Kostin, A. Gössel, V. Gubarev, W.-D. Möller, D. Reschke, K. Twarowski
    DESY, Hamburg, Germany
 
  SRF cavity Field Emission (FE) presents a major diagnostics instrument on the cavity performance, save the FE levels differ significantly from one cavity test setup to another, making the analysis difficult. A comparison study complimented with a direct calibration of FE in the cavities tested with different auxillaries and test stands (vertical / horizontal / module) is presented and discussed.  
poster icon Poster THPO035 [0.312 MB]