Author: Yamazaki, Y.
Paper Title Page
MOPMA20 Phase Stability of the RF Reference Line for the FRIB Linac 342
 
  • Q. Zhao, J.F. Brandon
    NSCL, East Lansing, Michigan, USA
  • D. Morris, Y. Yamazaki
    FRIB, East Lansing, Michigan, USA
 
  Funding: supported by the US Department of Energy Office of Science under Cooperative Agreement DE-SC0000661
The phase stability of rf reference line is usually quite restricted in a high energy linac (very long linac, very high frequency). Due to the change of the ambience temperature in the linac tunnel, the electrical length of reference rf cables may change significantly, which results in unacceptable phase changes in cavities. So, sometimes the reference line is very expensive, for example, made of optical fiber housed in a lengthy thermostatic chamber. The frequencies of FRIB linac cavities are 80.5 and 322 MHz (not very high). We also take advantage of the double-folded linac geometry and feed the reference line in the center of the linac to effectively reduced the reference line by 6 times. Our studies show that the FRIB linac can tolerate up to 12ps phase stability of the rf reference line. Therefore, no special treatment is needed for the reference line.
 
 
FRYBA1 Progress towards the Facility for Rare Isotope Beams 1453
 
  • J. Wei, N.K. Bultman, F. Casagrande, C. Compton, K.D. Davidson, J. DeKamp, B. Drewyor, K. Elliott, A. Facco, P.E. Gibson, T . Glasmacher, K. Holland, M.J. Johnson, S. Jones, D. Leitner, M. Leitner, G. Machicoane, F. Marti, D. Morris, J.A. Nolen, J.P. Ozelis, S. Peng, J. Popielarski, L. Popielarski, E. Pozdeyev, T. Russo, K. Saito, J.J. Savino, R.C. Webber, M. Williams, T. Xu, Y. Yamazaki, A. Zeller, Y. Zhang, Q. Zhao
    FRIB, East Lansing, USA
  • D. Arenius, V. Ganni
    JLAB, Newport News, Virginia, USA
  • A. Facco
    INFN/LNL, Legnaro (PD), Italy
  • R.E. Laxdal
    TRIUMF, Canada's National Laboratory for Particle and Nuclear Physics, Vancouver, Canada
  • J.A. Nolen
    ANL, Argonne, USA
 
  Funding: Work supported by the U.S. Department of Energy Office of Science under Cooperative Agreement DE-SC0000661
The Facility for Rare Isotope Beams (FRIB) is based on a continuous-wave superconducting heavy ion linac to accelerate all the stable isotopes to above 200 MeV/u with a beam power of up to 400 kW. At an average beam power approximately two-to-three orders-of-magnitude higher than those of operating heavy-ion facilities, FRIB stands at the power frontier of the accelerator family - the first time for heavy-ion accelerators. To realize this innovative performance, superconducting RF cavities are used starting at the very low energy of 500 keV/u, and beams with multiple charge states are accelerated simultaneously. Many technological challenges specific for this linac have been tackled by the FRIB team and collaborators. Furthermore, the distinct differences from the other types of linacs at the power front must be clearly understood to make the FRIB successful. This report summarizes the technical progress made in the past years to meet these challenges.