Author: Torun, Y.
Paper Title Page
MOP032 High Pressure RF Cavity Test at Fermilab 160
 
  • B.T. Freemire, P.M. Hanlet, Y. Torun
    IIT, Chicago, Illinois, USA
  • G. Flanagan, R.P. Johnson, M. Notani
    Muons, Inc, Batavia, USA
  • M.R. Jana, A. Moretti, M. Popovic, A.V. Tollestrup, K. Yonehara
    Fermilab, Batavia, USA
  • D.M. Kaplan
    Illinois Institute of Technology, Chicago, Illinois, USA
 
  Funding: Supported in part by DOE STTR grant DE-FG02-08ER86350
Operating a high gradient radio frequency cavity embedded in a strong magnetic field is an essential requirement for muon beam cooling. However, a magnetic field influences the maximum RF gradient due to focusing of dark current in the RF cavity. This problem is suppressed by filling the RF cavity with dense hydrogen gas. As the next step, we plan to explore the beam loading effect in the high pressure cavity by using a 400 MeV kinetic energy proton beam in the MuCool Test Area at Fermilab. We discuss the experimental setup and instrumentation.
 
 
TUP092 Multi-purpose 805 MHz Pillbox RF Cavity for Muon Acceleration Studies 1003
 
  • G.M. Kazakevich, G. Flanagan, R.P. Johnson, M.L. Neubauer, R. Sah
    Muons, Inc, Batavia, USA
  • K.C.D. Chan, A.J. Jason, S.S. Kurennoy, H.M. Miyadera, P.J. Turchi
    LANL, Los Alamos, New Mexico, USA
  • A. Moretti, M. Popovic, K. Yonehara
    Fermilab, Batavia, USA
  • Y. Torun
    IIT, Chicago, Illinois, USA
 
  Funding: Supported by DOE grant DE-FG-08ER86352.
An 805 MHz RF pillbox cavity has been designed and constructed to investigate potential muon beam acceleration and cooling techniques. The cavity can operate in vacuum or under pressure to 100 atmospheres, at room temperature or in an LN2 bath at 77 K. The cavity is designed for easy assembly and disassembly with bolted construction using aluminum seals. The surfaces of the end walls of the cavity can be replaced with different materials such as copper, aluminum, beryllium, or molybdenum, and with different geometries such as shaped windows or grid structures. Different surface treatments such as electro polished, high-pressure water cleaned, and atomic layer deposition are being considered for testing. The cavity has been designed to fit inside the 5-Tesla solenoid in the MuCool Test Area at Fermilab. Performance of the cavity, including initial conditioning and operation in the external magnetic field will be reported.