Paper | Title | Page |
---|---|---|
TUP240 | Coil Energizing Patterns for an Electromagnetic Variably Polarizing Undulator | 1277 |
|
||
Funding: The submitted manuscript has been created by UChicago Argonne, LLC, Operator of Argonne National Laboratory (“Argonne”). A new electromagnetic insertion device optimized for producing intense soft x-rays of variable polarization is under construction at the Advanced Photon Source. Most of the coil packs are powered by a main power supply; a few are powered separately so that magnetic fields at certain pole positions can be different. The undulator radiation depends sensitively on the chosen magnetic field pattern, and higher spectral harmonics may be shifted in energy. For some beamline experiments, it is important to reduce the so-called higher-order contamination to increase the signal-to-noise ratio. We present spectra and power densities calculated directly from realistic magnetic fields and discuss coil energizing patterns. Work supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract No. DE-AC02-06CH11357. |
||