WEP196 Single-Shot Longitudinal Phase Space Measurement Diagnostics Beamline Status at the Argonne Wakefield Accelerator 1858
 
  • M.M. Rihaoui, D. Mihalcea, P. Piot
    Northern Illinois University, DeKalb, Illinois, USA
  • W. Gai, J.G. Power
    ANL, Argonne, USA
 
  A single-shot longitudinal phase space diagnostics experiment is currently being commissioned at Argonne Wakefield Accelerator. The diagnostic beamline consists of two magnetic dipoles that bend the beam horizontally followed by an rf deflecting cavity that streaks the beam vertically. Using this configuration, the incoming longitudinal phase space can be mapped to a final (x,y) plane which can be directly measured, e.g., using a YAG screen. In this paper we discuss the limitations of such longitudinal phase space diagnostics and present some preliminary measurements.