Paper | Title | Page |
---|---|---|
WEOCS6 | The Injector Cryomodule for e-Linac at TRIUMF | 1469 |
|
||
The e-Linac project at TRIUMF, now funded, is specified to accelerate 10mA of electrons to 50MeV using 1.3GHz multi-cell superconducting cavities. The linac consists of three cryomodules; an injector cryomodule with one cavity and two accelerating modules with two cavities each. The injector module is being designed and constructed in collaboration with VECC in Kolkata. The design utilizes a unique box cryomodule with a top-loading cold mass. A 4K phase separator, 2K-4K heat exchanger and Joule-Thompson valve are installed within each module to produce 2K liquid. The design and status of the development will be presented. | ||
Slides WEOCS6 [13.002 MB] | ||