Author: Jaeckle, H.     [Jäckle, H.]
Paper Title Page
TUP183 Self-optimizing High Dynamic Power Supply Control 1175
 
  • X.H. Ke, F. Jenni
    FHNW, Windisch, Switzerland
  • H. Jäckle
    PSI, Villigen, Switzerland
 
  Funding: Paul Scherrer Institute, Switzerland
In 1999, the first fully digitally controlled magnet power supplies were put into operation at PSI (Paul Scherrer Institute, Switzerland). Today, approximately 1000 are in use at PSI and a multiple of that worldwide. This project aims at developing a high performance control scheme for a better dynamic behavior of today's magnet powers supplies, without reducing their excellent static behaviors. The resulting control strategy, an in situ identification based observer, combined with state space and proportional integral (SS-PI) control, leads to a significantly improved dynamic behavior of the existing power supplies. The whole commissioning, including system identification, as well as control parameter determination and optimization, is done automatically on the DSP with support of a PC. The control strategy has been implemented on the existing PSI controller and a 10A-corrector power supply, together with various magnets, by updating the software and/or firmware only. Currently, the new control strategy is being implemented and tested at PSI on a second generation Digital Power Electronic Control System (DPC) controller card.