Author: Edwards, H.T.
Paper Title Page
MOP121 Experimental Studies on Coherent Synchrotron Radiation in the Emittance Exchange Line at the Fermilab A0 Photoinjector 322
 
  • J.C.T. Thangaraj, M.D. Church, H.T. Edwards, A.S. Johnson, A.H. Lumpkin, P. Piot, J. Ruan, J.K. Santucci, Y.-E. Sun, R.M. Thurman-Keup
    Fermilab, Batavia, USA
 
  Future accelerators will employ advanced beam conditioning systems such as emittance exchangers to manipulate high brightness beams. Coherent synchrotron radiation (CSR) in the dipoles could limit the performance of the emittance exchanger. In this paper, we report the experimental and simulation studies on measuring coherent synchrotron radiation and its effects on the beam at the A0 photoinjector in the emittance exchange line. We show how CSR can be used to measure bunch length of the beam. We also report on the diagnostic scheme based on a weak skew quad in the emittance exchange line to study the CSR effects on the beam and other beam dynamics.  
 
WEP024 Near-ideal Emittance Exchange at the Fermilab Photoinjector 1543
 
  • A.S. Johnson, H.T. Edwards, A.H. Lumpkin, J. Ruan, J.K. Santucci, R.M. Thurman-Keup
    Fermilab, Batavia, USA
 
  The A0 Photoinjector at Fermilab is presently home to an emittance exchange (EEX) experiment. The emittance exchange beamline consists of a 3.9 GHz normal conducting deflecting mode cavity flanked by two doglegs. Electron bunches with charges of 250 pC and energy of 14.3 MeV are routinely sent through the exchanger. Here we present results of a 1:1 transverse and longitudinal emittance exchange.