WEP231 TRIUMF Cyclotron Beam Quality Improvement 1921
 
  • I.V. Bylinskii, R.A. Baartman, F.W. Bach, J.F. Cessford, G. Dutto, Y.-N. Rao, L.W. Root, R. Ruegg
    TRIUMF, Canada's National Laboratory for Particle and Nuclear Physics, Vancouver, Canada
 
  TRIUMF cyclotron for decades operated at 500 MeV. Recently, the two primary beamlines 1A and 2A, have been reconfigured for running at 480 MeV. The objective was to reduce beam losses caused by the electromagnetic stripping by 30%. The radiation losses reduction was confirmed with both online measurements and residual activation field mapping after 8 month of beam production. In order to improve stability of both primary beams, one of the harmonic coils was configured in Bz-mode to compensate for the beam split ratio fluctuations. Br-mode of this coil and two outer radius trim coils was utilized to correct the beam vertical position at extraction. Moreover, to make the beam spot position on the target stable and insensitive to any uncontrolled movement of the stripper foil due to heat distortion, the beamline front end optics was tuned to compensate the cyclotron's inherent dispersion. Details of these developments and improvements are discussed in the paper.