Paper |
Title |
Page |
TUPP037 |
Transverse Emittance Measurements of the REX-ISOLDE Beams in Preparation for the HIE-ISOLDE Commissioning |
513 |
|
- D. Voulot, M.A. Fraser, D. Lanaia
CERN, Geneva, Switzerland
- T. Olsson
MAX-lab, Lund, Sweden
|
|
|
The transverse emittance at the output of the REX-ISOLDE normal conducting linac has been measured at different energies in order to characterise the beam at injection to the future HIE-ISOLDE superconducting linac. The measurements were done with low intensity stable beams (~0.5 enA) in order to avoid compensation effects in the EBIS ion source and obtain representative measurements of the radioactive ion beam emittance. Emittances were measured using a slit-grid emittance meter and compared with results obtained with a quadrupole-scan (three-gradient) method. An analysis of the background suppression is presented and possible source of errors for both type of measurements are discussed.
|
|
|
Poster TUPP037 [2.084 MB]
|
|
|