A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Evtushenko, P.

Paper Title Page
TUP089 Electron Beam Timing Jitter and Energy Modulation Measurements at the JLab ERL 606
 
  • P. Evtushenko, S.V. Benson, D. Douglas, D.W. Sexton
    JLAB, Newport News, Virginia
 
 

When operating JLab high current ERL a strong reduction of the FEL efficiency was observed when increasing the average electron beam current. Investigating the FEL efficiency drop-off with the electron beam average current we also have measured the electron beam phase noise and the fast energy modulations. The so-called phase noise is essentially a variation of the time arrival of the electron bunches to the wiggler. That could be a very effective way of reducing the FEL efficiency if one takes in to account that the accelerator is routinely operated with the RMS bunch length of about 150 fs. Under a fast energy modulation we mean a modulation which can not be followed by the FEL due to its time constant, defined by the net gain. Such a modulation also could be a possible cause of the efficiency drop-off. Having the measurements made we could rule out the FEL efficiency drop-off due to either the fast energy modulation or the phase modulation. We also have learned a lot about instrumentation and techniques necessary for this kind of beam study. In this contribution we describe the used instrumentation and present results of the measurements.

 
TUP090 Optical Diffraction Radiation Measurements at CEBAF 609
 
  • P. Evtushenko, A. Freyberger
    JLAB, Newport News, Virginia
  • C. Liu
    CASA, newport news
  • A.H. Lumpkin
    Fermilab, Batavia
 
 

Optical diffraction radiation (ODR) is a promising technique, which could be used for non interceptive beam size measurements at future light sources. An ODR diagnostic station was designed and installed on a CEBAF transfer beam line. The purpose of the setup is to evaluate experimentally the applicability range for an ODR based non interceptive beam size monitor and to collect data to benchmark numerical modeling of the ODR. An extensive set of measurements were made at the electron beam energy of 4.5 GeV. The ODR measurements were made for both pulsed and CW electron beam of up to 80 uA. The wavelength dependence and polarization components of the ODR were studied using a set of insertable bandpass filters and polarizers. The typical transverse beam size during the measurements was ~150 microns. Complete ODR data, wavelength and polarization, were recorded for different beam sizes and intensities. The beam size was also measured with an optical transition radiation (OTR) as well as wire scanner located next to the ODR station. In this contribution we describe the experimental setup and present first results of the measurements with the comparison to the numerical simulations.