MOPWA041 |
Investigation of Radiation Damage of Insertion Devices at PETRA III due to Particle Losses using Tracking Results with SixTrack |
203 |
|
- G.K. Sahoo, M. Bieler, J. Keil, A. Kling, G. Kube, M. Tischer, R. Wanzenberg
DESY, Hamburg, Germany
|
|
|
PETRA-III is a 3rd generation synchrotron light source dedicated to users at 14 beam lines with 30 instruments since 2009. This operates in 40, 60, 480 or 960 bunches with 100 mA at an electron beam energy of 6 GeV. The horizontal beam emittance is 1nmrad while a coupling of 1% amounts to a vertical emittance of 10 pm-rad. The low emittance is achieved by deploying 80m of damping wigglers in two sections in west and north. Some of these undulators and wiggler devices have accumulated total radiation doses of about 100 kGy. Visible corrosion at the magnet structures of some permanent magnet undulators is seen. High dose rate measured regularly by Thermo Luminescent Dosimeters (TLDs) are monitored, which lead to inspect the magnetic field of all insertion devices in the PETRA tunnel. We are investigating particle losses with tracking simulation using SixTrack to gain a certain understanding of the radiation damage of the insertion devices. The goal is to develop a strategy to safeguard the insertion devices from further radiation damage.
|
|
DOI • |
reference for this paper
※ https://doi.org/10.18429/JACoW-IPAC2015-MOPWA041
|
|