Author: Tanaka, T.
Paper Title Page
TUPJE001 Design of Wavelength Tunable Coherent X-Ray Source 1604
 
  • J. Hyun
    Sokendai, Ibaraki, Japan
  • K. Endo
    TOYAMA Co., Ltd., Zama-shi, Kanagawa, Japan
  • K. Hayakawa, Y. Hayakawa, T. Sakai, T. Tanaka
    LEBRA, Funabashi, Japan
  • I. Sato
    Nihon University, Advanced Research Institute for the Sciences and Humanities, Funabashi, Japan
  • M. Satoh, M. Yoshida
    KEK, Ibaraki, Japan
 
  KEK, Nihon University and TOYAMA CO., Ltd. have been developing the compact shieldless coherent X-ray source that can change the X-ray energy (3-25keV). This X-ray is the Parametric X-ray radiation (PXR) generated by relativistic charged particles passed through a single crystal. It has features that are monochromaticity, coherence and diffraction large angle for the incident beam. These indicate to the possibility for the application to the medical treatment and diagnosis. Furthermore, we try to reduce the radiation which is mainly generated when the high energy beam is damped. This system consists of an accelerating, a decelerating structure and four bending magnets (theta: 90 degree). These structures are operated under low temperature to get the high Q-value for long beam pulse. PXR is generated by colliding with a single crystal after electron beam is accelerated up to 75 MeV. The bunch passed through the crystal is transported into a decelerator structure and then is decelerated to 3 MeV there. Q-magnets are arranged that dispersion function is zero except arc sections. We calculated the beam transport, PXR intensity and emittance blow up. We'll report these details.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-TUPJE001  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPWA014 Low Temperature Properties of 20 K Cooled Test Cavity for C-band 2.6-cell Photocathode RF Gun 2519
 
  • T. Tanaka, M. Inagaki, K. Nakao, K. Nogami, T. Sakai
    LEBRA, Funabashi, Japan
  • M.K. Fukuda, T. Takatomi, J. Urakawa, M. Yoshida
    KEK, Ibaraki, Japan
  • D. Satoh
    TIT, Tokyo, Japan
  • T.S. Shintomi
    Nihon University, Tokyo, Japan
 
  Funding: Work supported by the Photon and Quantum Basic Research Coordinated Development Program of the Japanese Ministry of Education, Culture, Sports, Science, and Technology (MEXT).
A cryogenic C-band 2.6-cell photocathode RF gun, which operates at 20 K, is under development at Nihon University for future possibility of use in a compact linac-driven X-ray source. The cavity material is 6N8 high purity copper, the RRR of which being expected to be higher than 3000. A 2.6-cell pi-mode test cavity was fabricated for investigation of the properties under low temperature of 20 K*. Ultraprecision machining and diffusion bonding of the cavity were carried out in KEK. The operating frequency of the RF gun cavity is 5712 MHz. The machining dimensions of the test cavity were determined by taking into account the contraction of copper from room temperature to 20 K by approximately 0.33 %. The resonant frequency observed at around 21 K was 5711.761 MHz, which is 185 kHz higher than the expected value that was deduced from the resonant frequency obtained at 23.5 degree C in vacuum and the linear expansion coefficient data for OFC copper by NIST**. The unloaded Q-value of 64500 obtained at 21 K is in agreement with the SUPERFISH calculation when the surface resistance of the RRR=3000 copper was specified with taking the anomalous skin effect into account.
* T. Tanaka et al., Proceedings of IPAC2014, 658-660, http://accelconf.web.cern.ch/AccelConf
/IPAC2014/papers/mopri030.pdf
** http://cryogenics.nist.gov/MPropsMAY/OFHC%20Copper/OFHCCopperrev.htm
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPWA014  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPWA015 RF Input Coupler for 20 K Cooled C-band 2.6-cell Photocathode RF Gun 2522
 
  • T. Tanaka, M. Inagaki, K. Nakao, K. Nogami, T. Sakai
    LEBRA, Funabashi, Japan
  • M.K. Fukuda, T. Takatomi, J. Urakawa, M. Yoshida
    KEK, Ibaraki, Japan
  • D. Satoh
    TIT, Tokyo, Japan
  • T.S. Shintomi
    Nihon University, Tokyo, Japan
 
  Funding: Work supported by the Photon and Quantum Basic Research Coordinated Development Program of the Japanese Ministry of Education, Culture, Sports, Science, and Technology (MEXT).
For future use in a compact linac-driven X-ray source, a cryo-cooled C-band photocathode RF gun is under development. The RF experiment on the basic 2.6-cell test cavity has shown that the unloaded Q-value of the cavity at 20 K can be explained by the surface resistance based on the anomalous skin effect. Since the cavity was intended for preliminary experiments of the low temperature RF properties*, a new test cavity with an RF input coupler has been designed. The basic structure of the accelerating cells has not been changed from the previous cavity. Avoiding an element with a low cooling efficiency such as the inner electrode in a coaxial coupler, a simpler cylindrical input coupler has been designed. The coupler consists of a cylindrical TM01 mode waveguide and a mode converter from a rectangular TE10 mode, with both elements placed on the accelerating axis. The structure and the dimensions of the coupler have been determined using the 3-D simulation code CST Studio so that the resonant frequency of the whole system and the coupling coefficient of the coupler meet the specifications of the RF gun. The new test cavity will be completed early in 2015 at KEK.
* T. Tanaka et al., Proceedings of IPAC2014, 658-660, http://accelconf.web.cern.ch/AccelConf
/IPAC2014/papers/mopri030.pdf
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPWA015  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)