Author: Liu, J.
Paper Title Page
TUPJE049 TPS Linac Relocation and Beam Test of the LTB Transfer Line 1731
 
  • H.-P. Chang, A.Y. Chen, C.L. Chen, Y.-S. Cheng, C.-S. Fann, K.T. Hsu, S.Y. Hsu, K.-K. Lin, Y.C. Lin, J. Liu, K.L. Tsai
    NSRRC, Hsinchu, Taiwan
 
  The Taiwan Photon Source (TPS) 150 MeV linac has been relocated from its 2011 test site to the TPS linac tunnel in 2014. After functional test of the linac hardware modules, the beam parameters were carefully examined at a 31-degree bend diagnostic beam line LTD (linac to beam dump) and compared with previous results. Then, the 150 MeV electron beam was delivered to the linac to booster transfer line (LTB) for beam commissioning. The beam optics matching at both the LTB entrance (i.e. linac exit) and the LTB exit (i.e. injection point of booster) was performed for injection optimization purpose. The LTB lattice setting was verified in the beam steering through LTD and LTB with the help of diagnostics tools such as beam profile monitors (SM) and beam position monitors (BPM). The overall performance of the linac and LTB will be described in this report.
#peace@nsrrc.org.tw
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-TUPJE049  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)