Author: Liebig, C.
Paper Title Page
TUPWA032 Progress in the Injector Upgrade of the LINAC II at DESY 1479
 
  • Y.C. Nie, M. Hüning, C. Liebig, M. Schmitz
    DESY, Hamburg, Germany
 
  A new injection system is under development for the LINAC II at DESY to improve the reliability of the machine and mitigate the radiological problem due to electron losses at energy of hundreds of MeV. It consists of a 100 kV triode DC gun, a 2.998 GHz pre-buncher, a novel 2.998 GHz hybrid buncher, and the dedicated beam transport and diagnostic elements. As the key components, the pre-buncher and the hybrid buncher realize a two-stage velocity bunching process including the ballistic bunching and the phase space rotation. Therefore, they produce a certain number of well-bunched 5 MeV micro-bunches from the input 2 ns-50 ns electron pulse for the downstream LINAC II. The overall upgrade plan, developments of the critical components, as well as the latest beam test results will be reported.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-TUPWA032  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)