Author: Horan, D.
Paper Title Page
TUPJE079 High Charge Development of the APS Injector for an MBA Upgrade 1828
 
  • C. Yao, M. Borland, J.R. Calvey, K.C. Harkay, D. Horan, R.R. Lindberg, N. Sereno, H. Shang, X. Sun, J. Wang
    ANL, Argonne, Illinois, USA
 
  Funding: Work supported by the U.S. Department of Energy, Office of Science, under Contract No. DE-AC02-06CH11357.
The APS MBA (multi-bend achromat) upgrade storage ring will employ a “swap out” injection scheme and requires a single-bunch beam with up to 20 nC from the injector. The APS injector, which consists of a 450-MeV linac, a particle accumulator ring (PAR), and a 7-GeV synchrotron (Booster), was originally designed to provide up to 6 nC of beam charge. High charge injector study is part of the APS upgrade R&D that explores the capabilities and limitations of the injector through machine studies and simulations, and identifies necessary upgrades in order to meet the requirements of the MBA upgrade. In the past year we performed PAR and booster high charge studies, implemented new ramp correction of the booster rap supplies, explored non-linear chromatic correction of the booster, etc. This report presents the results and findings.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-TUPJE079  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPTY008 Superconducting Harmonic Cavity for the Advanced Photon Source Upgrade 3267
 
  • M.P. Kelly, A. Barcikowski, J. Carwardine, Z.A. Conway, D. Horan, S.H. Kim, P.N. Ostroumov, G.J. Waldschmidt
    ANL, Argonne, Illinois, USA
  • J. Rathke, T. Schultheiss
    AES, Medford, New York, USA
 
  A new bunch lengthening cryomodule using a single-cell ‘higher-harmonic’ superconducting cavity (HHC) based on the TESLA shape and operating at the 4th harmonic (1408 MHz) of the main RF is under development at Argonne. The system will be used to improve the Touschek lifetime and increase the single-bunch current limit in the upgraded multibend achromat lattice of the Advanced Photon Source electron storage ring. The 4 K cryomodule will fit within one half of a straight section, ~2.5 meters, of the ring. The system will use a pair of moveable 20 kW (each) CW RF power couplers to adjust the loaded Q and extract power from the beam. This will provide the flexibility to adjust the impedance presented to the beam and run at various beam currents. Higher-order modes (HOMs) induced by the circulating electron beam will be extracted along the beam axis and damped using a pair of room temperature beam line absorbers. Engineering designs and the prototyping status for the cavity, power couplers and HOM absorbers are discussed.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPTY008  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)