Author: Cullen, C.
Paper Title Page
WEPWI060 Cryogenic Test of Double Quarter Wave Crab Cavity for the LHC High Luminosity Upgrade 3630
 
  • B. P. Xiao, S.A. Belomestnykh, I. Ben-Zvi, C. Cullen, L.R. Hammons, C. Marques, J. Skaritka, S. Verdú-Andrés, Q. Wu
    BNL, Upton, Long Island, New York, USA
  • L. Alberty, R. Calaga, O. Capatina
    CERN, Geneva, Switzerland
  • S.A. Belomestnykh, I. Ben-Zvi
    Stony Brook University, Stony Brook, USA
  • Z. Li
    SLAC, Menlo Park, California, USA
 
  Funding: Work partly supported by US LARP, by US DOE under contract No. DE-AC02-05CH11231 and through BSA under contract No. DE-AC02-98CH10886. Research supported by EU FP7 HiLumi LHC - Grant Agreement 284404.
A Proof-of-Principle (PoP) Double Quarter Wave Crab Cavity (DQWCC) was designed and fabricated for the Large Hadron Collider (LHC) luminosity upgrade. A vertical cryogenic test has been done at Brookhaven National Lab (BNL). The cavity achieved 4.5 MV deflecting voltage with a quality factor above 3×109. We report the test results of this design.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2015-WEPWI060  