JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for WEPMN049: Calibration of the Acceleration Voltage of Six Normal Conducting Cavities at ALBA

TY - CONF
AU - Bravo, B.
AU - Iriso, U.
AU - Marcos, J.
AU - Ocampo, J.R.
AU - Pérez, F.
AU - Salom, A.
AU - Solans, P.
ED - Henderson, Stuart
ED - Akers, Evelyn
ED - Satogata, Todd
ED - Schaa, Volker R.W.
TI - Calibration of the Acceleration Voltage of Six Normal Conducting Cavities at ALBA
J2 - Proc. of IPAC2015, Richmond, VA, USA, May 3-8, 2015
C1 - Richmond, VA, USA
T2 - International Particle Accelerator Conference
T3 - 6
LA - english
AB - ALBA is a 3Gev synchrotron light source located in Barcelona and operating with users since May 2012. The ALBA storage ring uses six room temperature cavities; each one fed by two 80kW IOTs amplifiers at 499.654 MHz. An accurate calibration of the RF voltage is required for the right adjustment of the beam synchronous phase. In addition, if the ring accommodates several RF cavities, these may not be optimally phased with respect to each other, complicating the calculation of the total RF voltage. In this paper, the steps to calibrate the accelerating voltage of the SR cavities will be presented and different methodologies to cross-check these calibrations.
PB - JACoW
CP - Geneva, Switzerland
SP - 3036
EP - 3038
KW - cavity
KW - synchrotron
KW - operation
KW - coupling
KW - pick-up
DA - 2015/06
PY - 2015
SN - 978-3-95450-168-7
DO - 10.18429/JACoW-IPAC2015-WEPMN049
UR - http://jacow.org/ipac2015/papers/wepmn049.pdf
ER -