RIS citation export for MOPWI010: Design and Development of a Beam Stablity Mechanical Motion System Diagnostic for the APS MBA Upgrade

TY - CONF
AU - Lill, R.M.
AU - Decker, G.
AU - Sereno, N.
AU - Yang, B.X.
ED - Henderson, Stuart
ED - Akers, Evelyn
ED - Satogata, Todd
ED - Schaa, Volker R.W.
TI - Design and Development of a Beam Stablity Mechanical Motion System Diagnostic for the APS MBA Upgrade
J2 - Proc. of IPAC2015, Richmond, VA, USA, May 3-8, 2015
C1 - Richmond, VA, USA
T2 - International Particle Accelerator Conference
T3 - 6
LA - english
AB - The Advanced Photon Source (APS) is currently in the conceptual design phase for the MBA lattice upgrade. In order to achieve long-term beam stability goals, a Mechanical Motion System (MMS) has been designed to monitor critical in-tunnel beam position monitoring devices. The mechanical motion generated from changes in chamber cooling water temperature, tunnel air temperature, beam current and undulator gap positon causes erroneous changes in beam position measurements causing drift in the X-ray beam position. The MMS has been prototyped and presently provides critical information on the vacuum chamber and BPM support systems. We report on first results of the prototype system installed in the APS storage ring.
PB - JACoW
CP - Geneva, Switzerland
SP - 1164
EP - 1166
KW - detector
KW - vacuum
KW - insertion
KW - insertion-device
KW - ground-motion
DA - 2015/06
PY - 2015
SN - 978-3-95450-168-7
DO - 10.18429/JACoW-IPAC2015-MOPWI010
UR - http://jacow.org/ipac2015/papers/mopwi010.pdf