JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for MOPTY082: Beam Instrumentation of the PXIE LEBT Beam Line

TY - CONF
AU - D'Arcy, R.T.P.
AU - Hanna, B.M.
AU - Prost, L.R.
AU - Scarpine, V.E.
AU - Shemyakin, A.V.
ED - Henderson, Stuart
ED - Akers, Evelyn
ED - Satogata, Todd
ED - Schaa, Volker R.W.
TI - Beam Instrumentation of the PXIE LEBT Beam Line
J2 - Proc. of IPAC2015, Richmond, VA, USA, May 3-8, 2015
C1 - Richmond, VA, USA
T2 - International Particle Accelerator Conference
T3 - 6
LA - english
AB - The PXIE accelerator is the front-end test stand of the proposed Proton Improvement Plan (PIP-II) initiative: a CW-compatible pulsed H⁻ superconducting RF linac upgrade to Fermilab’s injection system. The PXIE Ion Source and Low-Energy Beam Transport (LEBT) section are designed to create and transfer a 1–10 mA H⁻ beam, in either pulsed (0.001–16 ms) or DC mode, from the ion source through to the injection point of the RFQ. This paper discusses the range of diagnostic tools —Allison-type Emittance Scanner, Faraday Cup, Toroid, DCCT, electrically isolated diaphragms – involved in the commissioning of the beamline and preparation of the beam for injection into the RFQ.
PB - JACoW
CP - Geneva, Switzerland
SP - 1129
EP - 1132
KW - emittance
KW - ion
KW - solenoid
KW - ion-source
KW - diagnostics
DA - 2015/06
PY - 2015
SN - 978-3-95450-168-7
DO - 10.18429/JACoW-IPAC2015-MOPTY082
UR - http://jacow.org/ipac2015/papers/mopty082.pdf
ER -