Author: Wendt, M.
Paper Title Page
TUPRO013 Studies on Stochastic Cooling of Heavy Ions in the LHC 1030
 
  • M. Schaumann, J.M. Jowett, B. Salvant, M. Wendt
    CERN, Geneva, Switzerland
  • M. Blaskiewicz, S. Verdú-Andrés
    BNL, Upton, Long Island, New York, USA
 
  Future high luminosity heavy-ion operation of the LHC will be dominated by very rapid luminosity decay due to the large collision cross-section and, to a lesser extent, emittance growth from intra-beam scattering (IBS) due to the high bunch intensities. A stochastic cooling system could reduce the emittance far below its initial value and reduce the losses from debunching during collisions, allowing more of the initial beam intensity to be converted into integrated luminosity before the beams are dumped. We review the status of this proposal, system and hardware properties and potential locations for the equipment in the tunnel.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-TUPRO013  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPME008 Status of the CLIC-UK R&D Programme on Design of Key Systems for the Compact Linear Collider 1354
 
  • P. Burrows, R. Ainsworth, T. Aumeyr, D.R. Bett, N. Blaskovic Kraljevic, L.M. Bobb, S.T. Boogert, A. Bosco, G.B. Christian, L. Corner, F.J. Cullinan, M.R. Davis, D. Gamba, P. Karataev, K.O. Kruchinin, A. Lyapin, L.J. Nevay, C. Perry, J. Roberts, J. Snuverink, J.R. Towler
    JAI, Egham, Surrey, United Kingdom
  • R. Ainsworth, T. Aumeyr, S.T. Boogert, A. Bosco, P. Karataev, K.O. Kruchinin, L.J. Nevay, J.R. Towler
    Royal Holloway, University of London, Surrey, United Kingdom
  • P.K. Ambattu, G. Burt, A.C. Dexter, M. Jenkins, S. Karimian, C. Lingwood, B.J. Woolley
    Cockcroft Institute, Lancaster University, Lancaster, United Kingdom
  • L.M. Bobb, R. Corsini, D. Gamba, A. Grudiev, A. Latina, T. Lefèvre, C. Marrelli, M. Modena, J. Roberts, H. Schmickler, D. Schulte, P.K. Skowroński, J. Snuverink, S. Stapnes, F. Tecker, R. Tomás, R. Wegner, M. Wendt, W. Wuensch
    CERN, Geneva, Switzerland
  • J.A. Clarke, S.P. Jamison, P.A. McIntosh, B.J.A. Shepherd
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
  • N.A. Collomb, D.G. Stokes
    STFC/DL, Daresbury, Warrington, Cheshire, United Kingdom
  • L. Corner
    Oxford University, Physics Department, Oxford, Oxon, United Kingdom
  • W.A. Gillespie, R. Pan, M.A. Tyrk, D.A. Walsh
    University of Dundee, Nethergate, Dundee, Scotland, United Kingdom
  • R.M. Jones
    UMAN, Manchester, United Kingdom
 
  Six UK institutes are engaged in a collaborative R&D programme with CERN aimed at demonstrating key aspects of technology feasibility for the Compact Linear Collider (CLIC). We give an overview and status of the R&D being done on: 1) Drive-beam components: quadrupole magnets and the beam phase feed-forward prototype. 2) Beam instrumentation: stripline and cavity beam position monitors, an electro-optical longitudinal bunch profile monitor, and laserwire and diffraction and transition radiation monitors for transverse beam-size determination. 3) Beam delivery system and machine-detector interface design, including beam feedback/control systems and crab cavity design and control. 4) RF structure design. In each case, where applicable, we report on the status of prototype systems and performance tests with beam at the CTF3, ATF2 and CesrTA test facilities, including plans for future experiments.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-TUPME008  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME178 Status of the CLIC/CTF Beam Instrumentation R&D 3690
 
  • M. Wendt, A. Benot-Morell, B.P. Bielawski, L.M. Bobb, E. Bravin, T. Lefèvre, F. Locci, S. Magnoni, S. Mazzoni, R. Pan, J.R. Towler, E.N. del Busto
    CERN, Geneva, Switzerland
  • T. Aumeyr, S.T. Boogert, P. Karataev
    Royal Holloway, University of London, Surrey, United Kingdom
  • W.A. Gillespie, D.A. Walsh
    University of Dundee, Nethergate, Dundee, Scotland, United Kingdom
  • S.P. Jamison
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
  • A. Lyapin, J. Snuverink
    JAI, Egham, Surrey, United Kingdom
  • J.M. Nappa, S. Vilalte
    IN2P3-LAPP, Annecy-le-Vieux, France
 
  The Compact Linear Collider (CLIC) is an e+/e collider based on the two-beam acceleration principle, proposed to support precision high-energy physics experiments in the energy range 0.5-3 TeV. To achieve a high luminosity of up to 6e34cm-2s−1, the transport and preservation of a low emittance beam is mandatory. A large number and great variety of beam diagnostics instruments is foreseen to verify and guarantee the required beam quality. We present the status of the beam diagnostics developments and experimental results accomplished at the CLIC Test Facility (CTF), including new ideas for simplification and cost reduction of the CLIC beam instrumentation.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME178  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPRI058 Commissioning Status of the Advanced Superconducting Test Accelerator at Fermilab 2615
 
  • J. Ruan, R. Andrews, C.M. Baffes, D.R. Broemmelsiek, K. Carlson, B. Chase, M.D. Church, D.J. Crawford, E. Cullerton, J.S. Diamond, N. Eddy, D.R. Edstrom, E.R. Harms, A. Hocker, A.S. Johnson, A.L. Klebaner, M.J. Kucera, J.R. Leibfritz, A.H. Lumpkin, J.N. Makara, S. Nagaitsev, O.A. Nezhevenko, D.J. Nicklaus, L.E. Nobrega, P.S. Prieto, J. Reid, J.K. Santucci, G. Stancari, D. Sun, M. Wendt, S.J. Wesseln
    Fermilab, Batavia, Illinois, USA
  • P. Piot
    Northern Illinois University, DeKalb, Illinois, USA
 
  Funding: *Operated by Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the United States Department of Energy.
The Advanced Superconducting Test Accelerator (ASTA) is under construction at Fermilab. This accelerator will consist of a photo-electron gun, injector, ILC-type cryomodules, and multiple downstream beam-lines. Its purpose is to be a user-based facility for Advanced Accelerator R&D. . Following the successful commissioning of the photoinjector gun, a Tesla style 8-cavity cryomodule and a high gradient capture cavity have been cooled down to 2 K and powered commissioning and performance characterization has begun. We will report on the commissioning status and near-term future plans for the facility.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-WEPRI058  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)