Author: Tang, Z.X.
Paper Title Page
THPRI048 Design of an Accelerating Tube for a Standing-wave Accelerator based on Genetic Algorithm’s Optimal Calculation 3875
SUSPSNE090   use link to see paper's listing under its alternate paper code  
 
  • Z.X. Tang
    USTC, Hefei, Anhui, People's Republic of China
  • Y.J. Pei
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  A compact medical standing-wave (SW) electron accelerating tube has been designed that operating frequency is 2998MHz, operating mode is π/2, final energy is 6MeV and beam current is 100mA based on genetic algorithm (GA)’s optimal calculation. It employed a bi-periodic structure with nose cone shape. We performed the simulation experiment which proved that GA was feasible and gave a set of geometric parameter with higher shunt impedance. We performed tuning of the whole tube by CST MICROWAVE STUDIO and SUPERFISH and calculation of beam dynamics by ASTRA and Parmela in this paper. The total length of the tube is less than 300mm.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPRI048  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)