Author: Shemmary, A.
Paper Title Page
THPME109 EOS at CW Beam Operation at ELBE 3492
 
  • Ch. Schneider, M. Gensch, M. Kuntzsch, P. Michel, W. Seidel
    HZDR, Dresden, Germany
  • P.E. Evtushenko
    JLab, Newport News, Virginia, USA
  • Ç. Kaya
    Ankara University, Accelerator Technologies Institute, Golbasi / Ankara, Turkey
  • A. Shemmary, N. Stojanovic
    DESY, Hamburg, Germany
 
  The ELBE accelerator is a super conduction electron cw machine located at the Helmholtz Center Dresden Rossendorf Germany with 1 mA current, now tested for up to 2 mA. Besides other important diagnostics for setting up the machine for user beam time and further improvement of the machine – a THz source is momentary under commissioning – a EOS measuring station for bunch length measurements is locate right behind the second super conducting Linac. Measuring with a crystal in the vicinity of an up to 2 mA cw beam implies higher beam loss and also higher radiation exposure of the crystal and hence also a safety risk for the UHV conditions of the super conducting cavities in the case of crystal damage. Therefore the EOS measuring principle is adapted to larger measuring distances and also for beam requirements with lower bunch charge at ELBE. A description of the setup, considerations of special boundary conditions and as well results for 13 MHz cw beam operation are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME109  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)