  As part of the design of CLARA (Compact Linear Accelerator for Research and Applications), the proposed UK FEL test facility at Daresbury Laboratory, a high repetition rate S-band photoinjector RF gun is being developed. This gun will be able to operate at up to 400 Hz repetition rate in single bunch mode. We present the initial cavity design including its optimisation for the beam dynamics of CLARA. We also present the initial cooling design for the cavity which will enable the high repetition rates to be achieved.  