Author: Nishiyama, M.
Paper Title Page
THPME133 Bunch Length Measurement with 2-Cell RF-Deflector at Waseda University 3556
 
  • T. Takahashi, Y. Nishimura, M. Nishiyama, K. Sakaue, M. Washio
    Waseda University, Tokyo, Japan
  • T. Takatomi, J. Urakawa
    KEK, Ibaraki, Japan
 
  We have been studying on a system to measure the length of electron bunch generated by a photocathode rf electron gun at Waseda University. We adopted the rf-deflector system which can convert the longitudinal distribution to transverse by sweeping the electron bunch. By using HFSS, we optimized the design of the 2 cell rf-deflector which is operating on π-mode, dipole (TM110-like) mode at 2856 MHz. The fabrication and the tuning of the rf deflector have successfully processed. We have installed the rf-deflector in the accelerator system of Waseda University, and performed the measurement of the bunch length. It is confirmed that this rf-deflector has the temporal resolution of 167fs with 700kW supply when the beam energy is 4.8MeV. This means that our rf-deflector system has possibility to measure the ultra-short bunch length. In this conference, the rf-deflector system in Waseda University, the result of the bunch length measurement, the performance of the rf-deflector and the future plan will be reported.
Work supported by JSPS Grant-in-Aid for Scientific Research (A) 10001690 and the Quantum Beam Technology Program of MEXT.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME133  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)