Author: Mitsuhashi, T.M.
Paper Title Page
THPME080 Reflective Streak Camera Bunch Length Measurements at the Australian Synchrotron 3421
 
  • M.J. Boland, Y.E. Tan
    SLSA, Clayton, Australia
  • T.M. Mitsuhashi
    KEK, Ibaraki, Japan
 
  The bunch length of the 3 GeV electron storage ring at the Australian Synchrotron has been measured using reflective input optics feeding a streak camera. An Offner optical design was employed to reduce the chromatic broadening of the input optics of the streak camera. Using the reflective input optics the bunch length is measured to be 15% shorter than with the refractive input optics. The measured bunch length is now in good agreement with the model of the storage ring and the values are being used for calibration, monitoring and optimisation of the machine. The results of studies to characterise the streak camera shall also be presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME080  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)