Author: Metreveli, A.A.
Paper Title Page
THPME029 Upgrade of Heavy Ion Injector for ITEP-TWAC Facility 3283
 
  • V. Andreev, N.N. Alexeev, A.I. Balabin, M.M. Kats
    ITEP, Moscow, Russia
  • A.A. Metreveli
    MEPhI, Moscow, Russia
 
  A new scheme of heavy ion injector I-3 designed for improvement of accelerated beam parameters has been proposed for ITEP-TWAC Facility. It is based on the usage of two quarter-wave double gap resonators operated on 5 MHz with accelerating voltage of 3 MV per gap. Existing 2.5 MHz double gap resonator will be retuned for operational frequency of 5 MHz and new additional one will be built. The new injector optimized for acceleration of heavy ions with A/Z in the range of 3-10 will allow accelerating any ions from C to U with beam current up to10 mA. Results of both electrodynamics and beam dynamics simulations of the accelerating structures are presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME029  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)