WEPRI057 RF Control and DAQ Systems for the Upgraded Vertical Test Facility at Fermilab 2612
 
  • Y.M. Pischalnikov, R.H. Carcagno, F.L. Lewis, R. Nehring, R.V. Pilipenko, W. Schappert
    Fermilab, Batavia, Illinois, USA
 
  Funding: Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the U.S. Department of Energy.
The Fermilab Vertical Cavity Test Facility (VCTF) [1] is a used to test production cavities prior to their installation in cryomodules and to characterize the performance of research cavities as part of the extensive SRF cavity R&D program at FNAL. The performance of a variety of SRF cavities (325MHz, 650MHz, 1300MHz; bare and dressed) can be measured at VCTF. Recently FNAL upgraded the facility by adding two additional test stands (VTS2&3) in preparation for production of cavities for two new linear accelerators (LCLS II and PIP II). This paper provides an overview of the design features, technical parameters and experience with first operation of the upgraded RF control and DAQ systems.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-WEPRI057  