Author: Karnaukhov, I.M.
Paper Title Page
THPME201 Survey Network of NESTOR Facility 3754
SUSPSNE105   use link to see paper's listing under its alternate paper code  
 
  • O. Bezditko, V.E. Ivashchenko, I.M. Karnaukhov, A. Mytsykov, O.V. Ryezayev, A.Y. Zelinsky
    NSC/KIPT, Kharkov, Ukraine
 
  For successful operation of X-ray source NESTOR it is necessary that all the focusing elements should be installed in design position according to the designed lattice, which should provide a low emittance value and small beam size at the interaction point . Accuracies of NESTOR electromagnetic elements installation are 100 mkm in the transverse coordinate, 200 mkm in the longitudinal coordinate and 200 mrad for all three rotation freedom. To achieve these objectives coordinate net, which allows us to align the elements, was designed and developed in the hall of the NESTOR storage ring. The whole process is controlled by means of optical instruments and theodolite 3T2KP with angular accuracy of 2" and laser meter system LMS - 100, which measure the distance with micron accuracy. The final errors budget consists of the accuracy of the measuring instruments, the quality of elements manufacture and assembling. A well-planned methodology allows to realize the design parameters of the X-ray generator "NESTOR " and was proved by experiments of the facility.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME201  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)