Author: Jones, T.J.
Paper Title Page
WEPME083 VELA: A New Accelerator Technology Development Platform for Industry 2471
 
  • P.A. McIntosh, D. Angal-Kalinin, R.K. Buckley, S.R. Buckley, J.A. Clarke, P.A. Corlett, B.D. Fell, A.R. Goulden, C. Hill, F. Jackson, S.P. Jamison, J.K. Jones, L.B. Jones, A. Kalinin, L. Ma, J.W. McKenzie, K.J. Middleman, B.L. Militsyn, A.J. Moss, T.C.Q. Noakes, Y.M. Saveliev, D.J. Scott, B.J.A. Shepherd, R.J. Smith, S.L. Smith, T.T. Thakker, A.E. Wheelhouse, P.H. Williams
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
  • N. Bliss, G. Cox, G.P. Diakun, A. Gleeson, T.J. Jones, K. Robertson, M.D. Roper, E. Snedden
    STFC/DL, Daresbury, Warrington, Cheshire, United Kingdom
  • S.T. Boogert
    Royal Holloway, University of London, Surrey, United Kingdom
  • N.J. Boulding
    FMB Oxford, Oxford, United Kingdom
  • A. Lyapin
    JAI, Egham, Surrey, United Kingdom
  • E.J. Morton
    CXR Ltd, Guildford, United Kingdom
 
  The Versatile Electron Linear Accelerator (VELA) facility will provide enabling infrastructures targeted at the development and testing of novel and compact accelerator technologies, specifically through partnership with industry and aimed at addressing applications in medicine, health, security, energy and industrial processing. The facility has now been commissioned at Daresbury Laboratory and the facility is now being actively utilised by industrial groups who are able to take advantage of the variable electron beam parameters available on VELA to either demonstrate new techniques and/or processes or otherwise develop new technologies for future commercial realisation. Examples of which to be presented include; demonstration of a new cargo scanning process, characterisation of novel, high performance beam position monitors, as well as other technology development applications.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-WEPME083  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPRI045 Key Design Features of Crab-Cavity Cryomodule for HiLumi LHC 2580
 
  • S.M. Pattalwar, A.J. May, P.A. McIntosh, A.E. Wheelhouse
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
  • G. Burt, B.D.S. Hall
    Cockcroft Institute, Lancaster University, Lancaster, United Kingdom
  • O. Capatina
    CERN, Geneva, Switzerland
  • T.J. Jones, N. Templeton
    STFC/DL, Daresbury, Warrington, Cheshire, United Kingdom
  • T.H. Nicol
    Fermilab, Batavia, Illinois, USA
 
  A prototype Superconducting RF (SRF) cryomodule, comprising multiple compact crab cavities is foreseen to realise a local crab crossing scheme for the “Hi-Lumi LHC”, a project launched by CERN to increase the luminosity performance of LHC. A cryomodule with two cavities will be initially installed and tested on the SPS drive accelerator at CERN to evaluate performance with high-intensity proton beams. STFC in collaboration with, University of Lancaster, CERN and FNAL has developed a concept cryomodule that has overcome most of the critical challenges imposed by a series of boundary conditions arising from; the complexity of the cavity design, the requirement for multiple RF couplers, the close proximity to the second LHC beam pipe and the tight space constraints in the SPS tunnel. This paper highlights some of the key design features of the cryomodule with the results of the associated mechanical and thermal analysis.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-WEPRI045  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPRI048 Testing and Dressed Cavity Design for the HL-LHC 4R Crab Cavity 2589
 
  • B.D.S. Hall, G. Burt
    Cockcroft Institute, Lancaster University, Lancaster, United Kingdom
  • R. Calaga, S. Calatroni, E. Jensen, A. Macpherson, M. Navarro-Tapia
    CERN, Geneva, Switzerland
  • T.J. Jones, N. Templeton
    STFC/DL, Daresbury, Warrington, Cheshire, United Kingdom
  • A.J. May, P.A. McIntosh, S.M. Pattalwar, A.E. Wheelhouse
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
 
  The High luminosity upgrade to the LHC (HL-LHC) calls for crab cavities to reduce the luminosity loss due to the crossing angle and help provide luminosity levelling. The 4 Rod Crab Cavity (4RCC) is one of three proposed options under consideration. A bare cavity has been prototyped and has undergone recent vertical tests and the results are presented. The dressed cavity includes a power coupler, a lower order mode coupler and two HOM couplers will be presented and discussed.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-WEPRI048  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPRO051 Cavity Design for a S-Band Photoinjector RF Gun with 400 Hz Repetition Rate 2983
 
  • J.W. McKenzie, L.S. Cowie, P. Goudket, B.L. Militsyn
    STFC/DL/ASTeC, Daresbury, Warrington, Cheshire, United Kingdom
  • G. Burt
    Cockcroft Institute, Lancaster University, Lancaster, United Kingdom
  • T.J. Jones
    STFC/DL, Daresbury, Warrington, Cheshire, United Kingdom
  • V.V. Paramonov
    RAS/INR, Moscow, Russia
 
  As part of the design of CLARA (Compact Linear Accelerator for Research and Applications), the proposed UK FEL test facility at Daresbury Laboratory, a high repetition rate S-band photoinjector RF gun is being developed. This gun will be able to operate at up to 400 Hz repetition rate in single bunch mode. We present the initial cavity design including its optimisation for the beam dynamics of CLARA. We also present the initial cooling design for the cavity which will enable the high repetition rates to be achieved.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPRO051  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME185 Design and First Operation of a Silicon-based Non–invasive Beam Monitor 3712
 
  • T. Cybulski, L.J. Devlin, C.P. Welsch
    Cockcroft Institute, Warrington, Cheshire, United Kingdom
  • T. Cybulski, L.J. Devlin, K.P. Hennessy, C.P. Welsch
    The University of Liverpool, Liverpool, United Kingdom
  • T.J. Jones
    STFC/DL, Daresbury, Warrington, Cheshire, United Kingdom
  • A. Kacperek, B. Marsland, I. Taylor, A. Wray
    The Douglas Cyclotron, The Clatterbridge Cancer Centre NHS Foundation Trust, Wirral, United Kingdom
 
  Funding: Work supported by the EU under contract PITN-GA-2008-215080 and the STFC Cockcroft Institute Core Grant No. ST/G008248/1.
Non–invasive, highly accurate and reliable beam monitors are a desired aim of any beam diagnostics design. Knowledge of beam parameters is essential in fundamental research, industry or medical applications with varying demands. It is critical for the optimization of ion beams used for cancer treatment. Ocular tumor treatment at the Clatterbridge Cancer Center (CCC) uses a 60 MeV proton beam. Disturbances introduced to a beam by intercepting devices risk affecting its energy and energy spread, thereby limiting its effectiveness for treatment. The advantageous semi-circular structure of the LHCb Vertex Locator (VELO) detector has been investigated in the QUASAR Group. It is an interesting option for a non-invasive online beam monitor relying on beam ‘halo’ measurements without disturbing the part of the beam used for treatment. This contribution discusses the measurement method, setup design and integration within the CCC treatment beam line.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME185  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)