WEPME078 Experimental Test of the Prototype LLRF Systems for PAL-XFEL 2462
 
  • J. Hu, H. Heo, J.H. Hong, W.H. Hwang, H.-S. Kang, H.-S. Lee, C.-K. Min
    PAL, Pohang, Kyungbuk, Republic of Korea
 
  Two prototype LLRF systems were developed in collaboration with Pohang Accelerator Laboratory(PAL) and domestic companies. They are focused on the control of single klystron system to obtain mainly analogue performance. The low power test of the developed LLRF showed good performance previously. We experimentally tested LLRF in the klystron systems to see performance in the high power situation. They showed performance around the prototype specification for short time and relatively long time. During test some bugs are discovered and fixed.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-WEPME078  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPRO021 Results Produced after Measuring PAL-ITF Beam Diagnostic Instruments 2903
 
  • H. J. Choi, M.S. Chae, J.H. Hong, H.-S. Kang, S.J. Park
    PAL, Pohang, Kyungbuk, Republic of Korea
 
  Pohang Accelerator Laboratory (PAL) built a PAL-ITF at the end of 2012 to successfully complete PAL-XFEL in 2015. The PAL-ITF is equipped with various kinds of diagnostic equipment to produce high-quality electron bunches. An ICT and a Turbo-ICT were installed in the PAL-ITF. A Faraday Cup is installed at the end of the linear accelerator. These days, the quantity of electric charge occasionally is measured using a BPM Sum value. This paper focuses on the processes and results of electric charge quantity measurements using ICT, Turbo-ICT, FC and BPM. The PAL-ITF is equipped with Stripline-BPM. It is important to find a way to minimize measurement errors that can appear in the process of installing or measuring the BPM. For this, PAL-ITF separately measured the BPM electrode sensitivity and minimized BPM measurement errors through generally calibrating BPM devices by applying Lambertson's Method. A plan was made to minimize BPM measurement errors through applying the BPM electrical calibration method for BPM devices to be used by the PAL-XFEL. This paper examines the processes for checking the performance of the S-BPM installed in the PAL-ITF and the results of its measurements.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPRO021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)