Author: Hayashi, K.
Paper Title Page
TUPRI092 Improvement of the Position Monitor using White Light Interferometer for Measuring Precise Movement of Compact ERL Superconducting Cavities in Cryomodule 1787
 
  • H. Sakai, K. Enami, T. Furuya, M. Satoh, K. Shinoe, K. Umemori
    KEK, Ibaraki, Japan
  • T. Aoto, K. Hayashi, K. Kanzaki
    Tokyo Seimitsu Co. Ltd, Ibaraki, Japan
  • E. Cenni
    Sokendai, Ibaraki, Japan
  • M. Sawamura
    JAEA, Ibaraki-ken, Japan
 
  Alignment of superconducting cavities is one of the important issues for linear collider and/or future light source like ERL and X-FEL. To measure the cavity displacement under cooling to liquid He temperature more precisely, we newly developed the position monitor by using white light interferometer. This monitor is based on the measurement of the interference of light between the measurement target and the reference point. It can measure the position from the outside of the cryomodule. We applied this monitor to the main linac cryomodule of Compact ERL (cERL) and successfully measured the displacement during 2K cooling with the resolution of 10um. However, some drift come from outer temperature and humidity were observed. In this paper, we describe the upgraded version of this monitor to suppress these drift for cERL beam operation.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-TUPRI092  