Author: Hannah, B.S.
Paper Title Page
THPRI113 Spallation Neutron Source Cryogenic Test Facility Horizontal Test Apparatus Operation 4043
 
  • B. DeGraff, B.S. Hannah, T.S. Neustadt, J. Saunders
    ORNL RAD, Oak Ridge, Tennessee, USA
  • R. Afanador, M. Doleans, M.P. Howell, S.-H. Kim, C.J. McMahan
    ORNL, Oak Ridge, Tennessee, USA
 
  Funding: This work was supported by SNS through UT-Battelle, LLC, under contract DE-AC05-00OR22725 for the U.S. DOE.
The Spallation Neutron Source (SNS) has built Superconducting Radio Frequency (SRF) processing and testing facilities to support improvement programs and future upgrades. The Cryogenic Test Facility (CTF) system is capable of delivering liquid helium at 4.5K to different test apparatus in support of SRF testing. This paper describes the final stages of fabrication, commissioning and the initial operation of the Horizontal Test Apparatus (HTA). The HTA allows for cold testing of single jacketed medium-beta or high-beta SRF cavities. Heat loads, capacities, and other performance data collected during operation will be presented. Cavity testing lifecycle for plasma processing research and development will be discussed. System changes to allow for 2K helium operation in the HTA will also be addressed.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPRI113  