Author: Geng, H.
Paper Title Page
MOPRI090 Beam Distribution Transformation with SFMs at 3MeV C-ADS Beamline 824
 
  • H. Geng, P. Cheng, C. Meng, S. Pei, B. Sun, H.J. Wang, B. Xu, F. Yan, Y.L. Zhao
    IHEP, Beijing, People's Republic of China
 
  The C-ADS project is building a test facility at the Institute of High Energy Physics. The design goal of the test facility is 10MeV beam energy with a continuous beam current of 10mA. To sustain the 100kW CW beam power at the beam dump, a beam distribution transform system is designed. The Step Field Magnets (SFMs) are used to transform the beam distribution from Gaussian to uniform. In this test stand, two sets of SFMs will be employed to manipulate the beam distribution. At the first commissioning stage, the bump dump line will be connected to the Medium Energy Beam Transport-1 (MEBT1) to test the beam manipulation scheme. The design and error analysis of this 3MeV beam dump line will be discussed in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-MOPRI090  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME138 Dynamic Comparison With XAL and Tracewin Based on the Injector-I of China ADS Test Stand 3572
 
  • Y.L. Zhao, P. Cheng, H. Geng, C. Meng, S. Pei, B. Sun, H.J. Wang, B. Xu, F. Yan
    IHEP, Beijing, People's Republic of China
 
  The injector scheme I (injector-I) of China ADS test stand is a superconducting Linac which accelerates 10mA beam to 3.2MeV, 5MeV, 10MeV, and then transports it to the dump. The dump line is designed to meet the requirement of beam expansion at the three different energies. The XAL from SNS was selected for the commissioning of China ADS. Because the beam current is so high, the nonlinear space charge force cannot be omitted. As we know, XAL calculates the space charge force with linear resolver. So, whether it could display the beam exactly enough is an important issue to consider. As a preparation for beam commissioning, the virtual accelerator in XAL frame was built and tested. Here in this paper, the envelopes of the 5MeV and 10MeV lattices from general XAL mpx application are shown and compared with the multiparticle tracking code TraceWin.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME138  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME139 Emittance Measurement with Wire Scanners at CADS MEBT1 3575
 
  • H. Geng, P. Cheng, C. Meng, S. Pei, B. Sun, H.J. Wang, B. Xu, F. Yan, Y.L. Zhao
    IHEP, Beijing, People's Republic of China
 
  The C-ADS project has started beam commissioning. The ion source and LEBT has been commissioned successfully, while the RFQ is under conditioning. The Medium Energy Beam Transport line-1 (MEBT) is the place where extensive beam parameter measurement will be carried out. Beam emittance is one of the most critical parameters which have to characterized. In the C-ADS injector-I, the MEBT-1 has installed three wire scanners to measure the beam sizes. The transverse emittance measurement method using the wire scanners will be discussed in detail in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME139  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)