Author: Geithner, R.
Paper Title Page
THPME122 A SQUID-based Beam Current Monitor for FAIR 3524
 
  • R. Geithner, T. Stöhlker, W. Vodel
    HIJ, Jena, Germany
  • R. Geithner, R. Neubert, P. Seidel
    FSU Jena, Jena, Germany
  • F. Kurian, H. Reeg, M. Schwickert
    GSI, Darmstadt, Germany
  • T. Stöhlker
    IOQ, Jena, Germany
 
  A Cryogenic Current Comparator (CCC) was developed for the upcoming FAIR-Project, providing a non-destructive online monitoring of the beam current in the nA-range. The CCC was optimized for a lowest possible noise-limited current resolution together with a high system bandwidth. Therefore, the low temperature properties of ferromagnetic core materials used in the pick-up coil were investigated and different SQUID-systems were tested. In this contribution we present results of the completed Cryogenic Current Comparator for FAIR working in a laboratory environment, regarding the improvements in resolution and bandwidth due to the use of suitable ferromagnetic core materials and optimized SQUID-system components.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME122  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME103 Beam Current Monitors for FAIR 3483
 
  • M. Schwickert, H. Bräuning, F. Kurian, H. Reeg, A. Reiter
    GSI, Darmstadt, Germany
  • R. Geithner, W. Vodel
    HIJ, Jena, Germany
  • R. Neubert
    FSU Jena, Jena, Germany
 
  The FAIR (Facility for Antiproton and Ion Research) accelerator facility presently under construction at GSI will supply a wide range of beam intensities for physics experiments. Design beam intensities range from 2.5·1013 protons/cycle to be delivered to the pBar-target and separator for production of antiprotons, to beams of e.g. 109 ions/s in the case of slowly extracted beams. The large intensity range demands for dedicated beam current monitors for precise, non-destructive beam intensity measurements in the synchrotrons, transport lines and storage rings of the FAIR facility. This report describes GSI developments of purpose-built beam current monitors for the SIS100 synchrotron and high-energy beam transport lines (HEBT) of FAIR. Prototype measurements with a SQUID-based Cryogenic Current Comparator and a resonant beam charge transformer are presented, and possibilities for further upgrades are discussed.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME103  