Author: Focker, G.J.
Paper Title Page
THPME179 Beam Diagnostics Measurements at 3MeV of the LINAC4 H Beam at CERN 3694
 
  • F. Zocca, J.C. Allica Santamaria, M. Duraffourg, G.J. Focker, D. Gerard, B. Kolad, L. Lenardon, M. Ludwig, U. Raich, F. Roncarolo, M. Sordet, J. Tan, J. Tassan-Viol, C. Vuitton
    CERN, Geneva, Switzerland
  • A. Feschenko
    MIPT, Dolgoprudniy, Moscow Region, Russia
  • A. Feschenko
    RAS/INR, Moscow, Russia
 
  As part of the CERN LHC injector chain upgrade, LINAC4 will accelerate H ions to 160 MeV, replacing the old 50 MeV proton linac. The ion source, the Low Energy Beam Transfer (LEBT) line, the 3 MeV Radio Frequency Quadrupole and the Medium Energy Beam Transfer (MEBT) line hosting a chopper, have been first commissioned in a dedicated test stand and are now tested in the LINAC4 tunnel. Diagnostics devices are installed in the LEBT and MEBT line and in a movable diagnostics test bench which is temporarily added to the MEBT exit. The paper gives an overview of all the instruments used, including beam current transformers, beam position monitors, wire scanners and wire grids for transverse profile measurements, a longitudinal bunch shape monitor and a slit-and-grid emittance meter. The movable test bench also includes a spectrometer that allows measuring the beam energy spread in conjunction with a wire grid. The present understanding of the instrumentation performance is discussed and the measurement results that allowed characterizing the 3 MeV beam in the LINAC4 tunnel are summarized.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME179  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)