Author: Crofford, M.T.
Paper Title Page
WEPRI074 Status of SRF Facilities at SNS 2663
 
  • J. Saunders, R. Afanador, B. DeGraff, C.J. McMahan
    ORNL RAD, Oak Ridge, Tennessee, USA
  • M.T. Crofford, M. Doleans, M.P. Howell, S.-H. Kim, S.W. Lee, T.S. Neustadt, S.E. Stewart, W.H. Strong
    ORNL, Oak Ridge, Tennessee, USA
 
  Funding: This work was supported by SNS through UT-Battelle, LLC, under contract DE-AC05-00OR22725 for the U.S. DOE.
As a part or an ongoing process to maintain and improve the performance of its Superconducting Linac (SCL) the Spallation Neutron Source (SNS) is building facilities for processing and testing Superconducting Radio Frequency (SRF) cavities. Recently both a High Pressure Rinse (HPR) tool and a Vertical Test Apparatus (VTA) have been built and commissioned. The HPR is a commercially fabricated piece of equipment which is customized for the SNS application. The VTA was specified, designed and developed by the SNS. This paper will outline the design features as well as the commissioning results for both systems.
 