THPME141 Design of Beam Intensity Measurement System in Injector for HLS II 3581
 
  • C. Cheng, P. Lu, B.G. Sun, K. Tang, J. Xu, Y.L. Yang, Z.R. Zhou, J.Y. Zou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  A new beam intensity measurement (BIM) system has been developed and has been used in the upgrade project of HLS II. After the upgrading is accomplished, electron energy in Injector endpoint will increase from 200MeV to 800MeV to achieve the goal of top-off injector. Meanwhile, macro pulse width changes from 1us to 1ns and peak intensity from 50mA to 1A approximately. So three fast current transformers (FCTs) and two integrating current transformer (ICTs) are installed in Linac and Transport Line to measure single pass beam parameters. In this article, off-line calibration of beam transformer is elaborated. Since the fast pulse signals from beam transformer will be hugely distorted after they transmit from Injector vacuum chamber to the Injector beam diagnostic centre room after hundreds of meters long LMR-400 cable, signal recovery algorithm based on FFT/IFFT is used to re-appear the true original signal and calculate the calibration efficient. In the end, resolution and measurement result of the BIM system is presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME141  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME145 BPM Signal Channel Characterization Test based on TDR for HLS II Storage Ring 3593
 
  • J.J. Zheng, C. Cheng, P. Lu, Q. Luo, B.G. Sun, Y.L. Yang, Z.R. Zhou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  A new BPM system on the upgraded Hefei light source (HLSII) storage ring is installed. Before the machine commissioning, the BPM system should be carefully tested, such as the conductivity and integrity of BPM signal channels from button electrodes to digital beam position processors (pickups, cables and connectors). This paper presents an experience of signal channel test based on time domain reflection (TDR) for HLS II storage ring BPM system. Basing on the wave propagation method, an analytic expression for the signal from TDR on BPM signal channel is briefly introduced. The conductivity and integrity of the BPM signal channels can be verified by comparing the TDR waveform to theory signal. All the BPM signal channels are tested by the TDR in order to verify electronic characteristic and the usability. And some breakdowns are analysed and handled.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME145  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)