Author: Blaum, K.
Paper Title Page
THPME121 The Status of the Diagnostic System at the Cryogenic Storage Ring CSR 3521
 
  • M. Grieser, A. Becker, K. Blaum, S. George, C. Krantz, S. Vogel, A. Wolf, R. von Hahn
    MPI-K, Heidelberg, Germany
 
  The cryogenic storage ring (CSR) at MPI für Kernphysik is an electrostatic storage ring for low velocity phase space cooled ion beams. Among other experiments cooling and storage of molecular ions in their rotational ground state is projected. The stored beam current will be in the range of 1 nA - 1 μA. The resulting low signal strengths on the beam position pickups, current monitors and Schottky monitor put strong demands on these diagnostics tools. Methods and systems were developed to measure the profile of the ion beam. In the paper a summary of the CSR diagnostics tools and diagnosis of the first stored ion beam will be given.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME121  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)