Author: Andersson, Å.
Paper Title Page
THPME169 Status of the New Beam Size Monitor at SLS 3662
 
  • J. Breunlin, Å. Andersson
    MAX-lab, Lund, Sweden
  • N. Milas
    LNLS, Campinas, Brazil
  • M. Rohrer, Á. Saá Hernández, V. Schlott, A. Streun
    PSI, Villigen PSI, Switzerland
 
  The Swiss Light Source (SLS) campaign on vertical emittance minimization and measurement required a beam size monitor with the ability to verify a sub-pmrad vertical emittance. This corresponds to a beam height of less than 4 μm. Within the TIARA Work Package ‘SLS Vertical Emittance Tuning’ a new beam size monitor was designed and built. The monitor is based on the imaging of the pi-polarized synchrotron radiation (SR) in the visible and UV spectral ranges. Besides imaging the monitor provides interferometric methods using vertically or horizontally polarized SR. With these complementary methods the consistency of beam size measurements is verified. An intermediate configuration of the monitor beamline using a lens as the focusing element has been commissioned in 2013. With this setup a vertical beam size of 4.8±0.5 μm, corresponding to a vertical emittance of 1.7±0.4 pmrad has been measured. During 2014 the monitor was commissioned in its final configuration with a toroidal mirror. The use of reflective optics allows wider bandwidth imaging and thus higher intensity. We report on challenges during commissioning and present first images of SR taken with the toroidal mirror.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME169  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)