Author: Wang, S.H.
Paper Title Page
THPME020 Design of a Test Cryomodule for IMP ADS-Injector II 3546
 
  • L. Wang, Y. Liu, S. Sun, J. Wang, S.Y. Wang, S.H. Wang
    SINAP, Shanghai, People's Republic of China
  • X.L. Guo
    JiangShu University, Jiangsu Province, People's Republic of China
 
  Two cryomodules are to be applied for the Injector II of the Accelerator Driven Sub-critical System. Each of them will contain 8 superconducting HWR cavities and 9 superconducting solenoids. In order to test the performance of the HWR cavities and validate related technique for cooling of cavities and solenoids together, a test cryomodule (TCM1) including one HWR cavity and two solenoids was developed. The design of the TCM1 cryostat was carried out by the Shanghai Institute of Applied Physics, CAS. Both the cavity and the solenoids will work at 4.4 K by bath cooling. The fast cooling down for the cavity from 100 K to 120 K is required to avoid degrading of the cavity performance. Before energization, the solenoids can be warmed up to above 10 K and re-cooled down for degaussing. The TCM1 can not only be cooled by using the dewar-filling system, but also operated by the refrigerator system. The main components of the cryostat include vacuum chamber, thermal shields, magnet current leads, cooling circuit, and cold mass support assembly. This paper presents the detailed design of the TCM1 cryostat.