Author: Wang, G.Y.
Paper Title Page
WEPME023 Study of the Vibration of the AC Dipole and Magnetic Measurement Girder for CSNS/RCS 2980
 
  • R.H. Liu, L. Kang, H. Qu, G.Y. Wang, H.J. Wang, J. S. Zhang
    IHEP, Beijing, People's Republic of China
 
  The dipole magnet of the China Spallation Neutron Source Rapid-cycling Synchrotron (RCS) will be operated at a 25Hz sinusoidal alternating current which causes severe vibration. The vibration will influence the long-term safety and reliable operation of the magnet. By taking the magnet and magnetic measurement girder as a specific model system, a method for analyzing and studying the dynamic characteristic of the system is put forward by combining theoretical calculation with experimental testing. And the ctive vibration of magnet is different with passive vibration which was causes by ground vibration, so a new isolator was designed to decrease the vibratory force and avoid the resonance phenomenon.