MOPEA006 Operation and Performance Upgrade of the SOLEIL Storage Ring 73
 
  • A. Nadji, F. Bouvet, P. Brunelle, A. Buteau, L. Cassinari, M.-E. Couprie, N. Hubert, M. Labat, J.-F. Lamarre, P. Lebasque, A. Lestrade, A. Loulergue, P. Marchand, J.L. Marlats, L.S. Nadolski, R. Nagaoka, M.-A. Tordeux
    SOLEIL, Gif-sur-Yvette, France
 
  SOLEIL delivers photons to 26 beamlines and 3 new ones are under construction together with the femtoslicing project. Up to 5 filling patterns are available for the users including a low alpha mode; all of them are in Top-up injection. The beam current for the users has been increased to 430 mA in the multibunch mode. The Storage Ring (SR) is running with a new optics incorporating an additional quadrupole triplet in one long straight section. The beam position stability remains excellent. Vertical positions from the dipole X-BPMs have been included in the orbit feedbacks loop with very encouraging results. A feedback loop maintaining the emittance coupling close to 1% for any Insertion Devices (IDs) configuration has been implemented. Up to 25 very diverse IDs are now installed on the SR, and several others are under design or construction. In house developments are being carried out in several domains such as construction of SR dipole power supply spare and of 70 kW-500 MHz solid state amplifiers, design of a pulsed multipole magnet for injection, and a Robinson wiggler, as well as a feasibility study of a local reduction of the emittance in one of the long straight sections.  
 
WEPFI005 Simulations and RF Measurements of the Fundamental and Higher Order Modes of the ThomX 500 MHz Cavity 2711
 
  • M. El Khaldi, I.V. Drebot, P. Lepercq, R. Marie, B. Mercier, T. Roulet, A. Variola, F. Wicek
    LAL, Orsay, France
  • H.D. Dias, M.D. Diop, M.E. El Ajjouri, R. Lopes, A. Loulergue, P. Marchand, F. Ribeiro, R. Sreedharan
    SOLEIL, Gif-sur-Yvette, France
 
  The RF system of the ThomX* storage ring consists in a 500 MHz single cell copper cavity of the ELETTRA type, powered with a 50 kW CW solid state amplifier, and the associated Low Level RF feedback and control loops. The low operating energy of 50 – 70 MeV makes the impedances of the cavity higher order modes (HOMs) particularly critical for the beam stability. Their parasitic effects on the beam can be cured by HOM frequency shifting techniques, based on a fine temperature tuning and a dedicated plunger. A typical cavity temperature stability of ± 0.05°C within a range from 35 up to 80 °C can be achieved by a precise control of its water cooling temperature. On the other hand, the tuning of the cavity fundamental mode is achieved by changing its axial length by means of a mechanical tuner. In order to insure a fine control of the HOM frequencies, a good knowledge of their characteristics is mandatory. The main parameters of the fundamental and of the HOMs up to 4 GHz have been calculated using the HFSS and CST MWS codes. Preliminary measurements results have been obtained and show a good agreement with the simulations.