Paper |
Title |
Page |
MOPME018 |
BEAM OSCILLATION MONITOR FOR THE MULTI-BUNCH BEAM |
506 |
|
- T. Naito, S. Araki, H. Hayano, K. Kubo, S. Kuroda, T. Okugi, N. Terunuma, J. Urakawa
KEK, Ibaraki, Japan
|
|
|
In order to observe the motion of bunch-by-bunch beam oscillation of multi-bunch in the storage ring, we developed two measurement tools. One is a signal process electronics circuit using fast analogue switches. The circuit picks up one of the selected bunch signal of the beam position monitor from the multi-bunch. The selected beam position signal can be processed as a single bunch beam. By changing the gate timing, arbitrary bunch signal can be selected. The other is a waveform memory using a high bandwidth oscilloscope. The long waveform memory of the oscilloscope has a capability to acquire the multi-turn waveform of the button electrode signals. The beam test of the circuit has been carried out at KEK-ATF damping ring in the cases of 2.8ns bunch spacing and 5.6ns bunch spacing, respectively. The detail of the hardware and the result of the beam test are reported.
|
|
|
MOPWA052 |
Short Range Wakefield Measurements of High Resolution RF Cavity Beam Position Monitors at ATF2 |
792 |
|
- J. Snuverink, S.T. Boogert, F.J. Cullinan, Y.I. Kim, A. Lyapin
JAI, Egham, Surrey, United Kingdom
- K. Kubo, T. Okugi, T. Tauchi, N. Terunuma, J. Urakawa
KEK, Ibaraki, Japan
- G.R. White
SLAC, Menlo Park, California, USA
|
|
|
Cavity beam position monitors (CBPM) have been used in several accelerator facilities and are planned to be used in future accelerators and light sources. High position resolution up to tens of nanometres has been achieved, but short range wakefields are a concern, especially for small beam emittances. This paper presents the wakefield calculations as well as the first measurements of the CBPM-generated short range wakefields performed at the Accelerator Test Facility (ATF2).
|
|
|
TUPME045 |
Turn-by-turn Measurements in the KEK-ATF |
1664 |
|
- Y. Renier, Y. Papaphilippou, R. Tomás, M. Wendt
CERN, Geneva, Switzerland
- N. Eddy
Fermilab, Batavia, USA
- K. Kubo, S. Kuroda, T. Naito, T. Okugi, N. Terunuma, J. Urakawa
KEK, Ibaraki, Japan
|
|
|
The ATF damping ring has been upgraded with new read-out electronics for the beam position monitors (BPM), capable to acquire the beam orbits on a turn-by-turn basis, as well as in a high resolution averaging mode. The new BPM system allows to improve optic corrections and to achieve an even smaller vertical emittance (<2pm). Experimental results are presented based on turn-by-turn beam orbit measurements in the ring, for estimating the beta functions and dispersion along the lattice. A fast method to measure spectral line amplitude in a few turns is also presented, including the evaluation of chromaticity.
|
|
|