Author: Yip, K.
Paper Title Page
MOPPC025 RHIC Polarized Proton Operation in Run 12 184
 
  • V. Schoefer, L. A. Ahrens, A. Anders, E.C. Aschenauer, G. Atoian, M. Bai, J. Beebe-Wang, M. Blaskiewicz, J.M. Brennan, K.A. Brown, D. Bruno, R. Connolly, T. D'Ottavio, A. Dion, K.A. Drees, W. Fischer, C.J. Gardner, J.W. Glenn, X. Gu, M. Harvey, T. Hayes, L.T. Hoff, H. Huang, R.L. Hulsart, A. Kirleis, J.S. Laster, C. Liu, Y. Luo, Y. Makdisi, G.J. Marr, A. Marusic, F. Méot, K. Mernick, R.J. Michnoff, M.G. Minty, C. Montag, J. Morris, S. Nemesure, A. Poblaguev, V. Ptitsyn, V.H. Ranjbar, G. Robert-Demolaize, T. Roser, W.B. Schmidke, F. Severino, D. Smirnov, K.S. Smith, D. Steski, S. Tepikian, D. Trbojevic, N. Tsoupas, J.E. Tuozzolo, G. Wang, M. Wilinski, K. Yip, A. Zaltsman, A. Zelenski, K. Zeno, S.Y. Zhang
    BNL, Upton, Long Island, New York, USA
 
  Successful RHIC operation with polarized protons requires meeting demanding and sometimes competing goals for maximizing both luminosity and beam polarization. In Run 12 we sought to fully integrate into operation the many systems that were newly commissioned in Run 11 as well as to enhance collider performance with incremental improvements throughout the acceleration cycle. For luminosity maximization special attention was paid to several possible source of emittance dilution along the injector chain, in particular to optical matching during transfer between accelerators. Possible sources of depolarization in the AGS and RHIC were also investigated including the effects of local coupling and low frequency (10 Hz) oscillations in the vertical equilibrium orbit during the RHIC ramp. The results of a fine storage energy scan made in an effort to improve store polarization lifetime are also reported in this note.  
 
TUPPC060 Beam Optics and the pp2pp Setup of the STAR Experiment at RHIC 1311
 
  • P.H. Pile, W. Guryn, J.H. Lee, S. Tepikian, K. Yip
    BNL, Upton, Long Island, New York, USA
 
  Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy.
The newly installed forward detector system at the STAR experiment at RHIC measures small angle elastic and inelastic scattering of polarized protons on polarized protons. The detector system makes use of a pair of Roman Pot (RP) detectors, instrumented with silicon detectors, and located on either side of the STAR intersection region downstream of the DX and D0 dipoles and quadrupole triplets. The parallel to point optics is designed so that scattering angles are determined from position measurements at the RP's with small error. The RP setup allows measurement of position and angle for a subset of the scattered protons. These measured position/angle correlations at the RP's can be compared with optics model predictions to get a measure of the accuracy of the quadrupole triplet current settings. The current in each quadrupole in the triplets is comprised of sums and differences of up to six power supplies and an overall 1% error in the triplet field strengths results in a 4% error in four-momentum transfer squared. This technique is also useful to check the polarity of the skew elements located in each quadrupole triplet. Results of the analysis will be presented.
 
 
WEPPR018 Beam Experiments towards High-intensity Beams in RHIC 2979
 
  • C. Montag, L. A. Ahrens, M. Blaskiewicz, J.M. Brennan, K.A. Drees, W. Fischer, T. Hayes, H. Huang, K. Mernick, G. Robert-Demolaize, K.S. Smith, R. Than, P. Thieberger, K. Yip, K. Zeno, S.Y. Zhang
    BNL, Upton, Long Island, New York, USA
 
  Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy.
Proton bunch intensities in RHIC will be increased from 2*1011 to 3*1011 protons per bunch to increase the luminosity, together with head-on beam-beam compensation using electron lenses. To study the feasibility of the intensity increase, beam experiments are being performed. Recent experimental results will be presented.