Author: Tepikian, S.
Paper Title Page
MOPPC022 Off-momentum Dynamic Aperture for Lattices in the RHIC Heavy Ion Runs 175
 
  • Y. Luo, M. Bai, M. Blaskiewicz, W. Fischer, X. Gu, A. Marusic, T. Roser, S. Tepikian, S.Y. Zhang
    BNL, Upton, Long Island, New York, USA
 
  Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy.
In this article we calculate and compare the off-momentum dynamic aperture for lattices with different phase advances per FODO cell in the RHIC heavy ion runs. A lattice with an increased phase advance was adopted in 2008-2011 to reduce transverse emittance growth rates from intra-beam scattering. However, during these runs, a large beam loss was observed with longitudinal RF re-bucketing which increased the momentum spread. With operational transverse stochastic cooling in the 2011 RHIC heavy ion run, the transverse intra-beam scattering emittance growth was eliminated, and the beam loss during stores was determined by the off-momentum aperture and burn-off from luminosity. We investigate the possibilities to increase the off-momentum dynamic aperture that would lead to an increase in the integrated luminosity.
 
 
MOPPC025 RHIC Polarized Proton Operation in Run 12 184
 
  • V. Schoefer, L. A. Ahrens, A. Anders, E.C. Aschenauer, G. Atoian, M. Bai, J. Beebe-Wang, M. Blaskiewicz, J.M. Brennan, K.A. Brown, D. Bruno, R. Connolly, T. D'Ottavio, A. Dion, K.A. Drees, W. Fischer, C.J. Gardner, J.W. Glenn, X. Gu, M. Harvey, T. Hayes, L.T. Hoff, H. Huang, R.L. Hulsart, A. Kirleis, J.S. Laster, C. Liu, Y. Luo, Y. Makdisi, G.J. Marr, A. Marusic, F. Méot, K. Mernick, R.J. Michnoff, M.G. Minty, C. Montag, J. Morris, S. Nemesure, A. Poblaguev, V. Ptitsyn, V.H. Ranjbar, G. Robert-Demolaize, T. Roser, W.B. Schmidke, F. Severino, D. Smirnov, K.S. Smith, D. Steski, S. Tepikian, D. Trbojevic, N. Tsoupas, J.E. Tuozzolo, G. Wang, M. Wilinski, K. Yip, A. Zaltsman, A. Zelenski, K. Zeno, S.Y. Zhang
    BNL, Upton, Long Island, New York, USA
 
  Successful RHIC operation with polarized protons requires meeting demanding and sometimes competing goals for maximizing both luminosity and beam polarization. In Run 12 we sought to fully integrate into operation the many systems that were newly commissioned in Run 11 as well as to enhance collider performance with incremental improvements throughout the acceleration cycle. For luminosity maximization special attention was paid to several possible source of emittance dilution along the injector chain, in particular to optical matching during transfer between accelerators. Possible sources of depolarization in the AGS and RHIC were also investigated including the effects of local coupling and low frequency (10 Hz) oscillations in the vertical equilibrium orbit during the RHIC ramp. The results of a fine storage energy scan made in an effort to improve store polarization lifetime are also reported in this note.  
 
TUPPC060 Beam Optics and the pp2pp Setup of the STAR Experiment at RHIC 1311
 
  • P.H. Pile, W. Guryn, J.H. Lee, S. Tepikian, K. Yip
    BNL, Upton, Long Island, New York, USA
 
  Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy.
The newly installed forward detector system at the STAR experiment at RHIC measures small angle elastic and inelastic scattering of polarized protons on polarized protons. The detector system makes use of a pair of Roman Pot (RP) detectors, instrumented with silicon detectors, and located on either side of the STAR intersection region downstream of the DX and D0 dipoles and quadrupole triplets. The parallel to point optics is designed so that scattering angles are determined from position measurements at the RP's with small error. The RP setup allows measurement of position and angle for a subset of the scattered protons. These measured position/angle correlations at the RP's can be compared with optics model predictions to get a measure of the accuracy of the quadrupole triplet current settings. The current in each quadrupole in the triplets is comprised of sums and differences of up to six power supplies and an overall 1% error in the triplet field strengths results in a 4% error in four-momentum transfer squared. This technique is also useful to check the polarity of the skew elements located in each quadrupole triplet. Results of the analysis will be presented.
 
 
TUPPC061 Commissioning of a beta∗ Knob for Dynamic IR Correction at RHIC 1314
 
  • G. Robert-Demolaize, A. Marusic, S. Tepikian, S.M. White
    BNL, Upton, Long Island, New York, USA
 
  Funding: Work supported by Brookhaven Science Associates, LLC under Contract No. DE-AC02-98CH10886 with the U.S. Department of Energy.
In addition to the recent optics correction technique demonstrated at CERN and applied at RHIC, it is important to have a separate tool to control the value of the beta functions at the collision point (beta∗). This becomes even more relevant when trying to reach high level of integrated luminosity while dealing with emittance blow-up over the length of a store, or taking advantage of compensation processes like stochastic cooling. Algorithms have been developed to allow modifying independently the beta function in each plane for each beam without significant increase in beam losses. The following reviews the principle of such algorithms and their experimental implementation as a dynamic beta-squeeze procedure.